Detection Of Escherichia coli In Water Using Capacitance Biosensor

Authors

  • Arwa Mujahed Department of Applied Chemistry and Biology, Faculty of Applied Science, Palestine Polytechnic University, Hebron, Palestine Author
  • Mohammed Alqaisi Department of Electrical Engineering, Faculty of Engineering, Palestine Polytechnic University, Hebron, Palestine Author

DOI:

https://doi.org/10.61856/mr5mqp71

Keywords:

Capacitance biosensors, Capacitance measuring circuit, E.Coli, Concentration ,Water contamination, Bacteria detection

Abstract

Pathogenic bacteria that are the main causative agent for biological contamination of water have always posed one of the most serious threats to public health, and continue to be specifically dangerous with the rise in antibiotic resistance. The incidence of these infectious agents needs rapid, point-of-care and real-time sensors for their detection and monitoring. Therefore, continuous real-time monitoring provides better microbiological control of the water and helps prevent contaminated water from reaching the households. In this research we have developed a method to detect E.coli (Escherichia coli) bacteria in water depending upon a large scale capacitance biosensor in the presence and absence of E.coli cells. First we show that the sensor is able to detect E. coli (Gram-negative) bacteria in water samples. Next, we demonstrate the sensor’s ability to measure the bacteria concentration suspended in water sample by comparing the results to those obtained by the traditional measurement using spectrophotometer. The results determine a correlation between the capacitance measurement and the real bacterial concentration which indicate an inversely relationship between the bacterial concentration and the capacitance measurement. Our investigations show that the capacitance biosensor has the potential to be extremely effective at detecting sudden bacterial contaminations found in drinking water in real-time and it is promising for the low-cost monitoring of bacterial growth and the detection of specific E.coli concentration due to the consistency and ease-of-use of capacitance measurements.

References

[1] Quiroz, K. L., Rodriguez, N. G., Murinda, S., & Ibekwe, M. (2018). Determination of the water quality of a constructed wetland monitoring fecal indicator bacteria.

[2] Lazcka, O., Del Campo, F. J., & Munoz, F. X. (2007). Pathogen detection: A perspective of traditional methods and biosensors. *Biosensors and Bioelectronics, 22*(7), 1205–1217. https://doi.org/10.1016/j.bios.2006.06.036

[3] Toze, S. (1999). PCR and the detection of microbial pathogens in water and wastewater. *Water Research, 33*(17), 3545–3556. https://doi.org/10.1016/S0043-1354(99)00071-8

[4] Haglund, J. R., Ayres, J. C., Paton, A. M., Kraft, A. A., & Quinn, L. Y. (1964). Detection of Salmonella in eggs and egg products with fluorescent antibody. *Applied Microbiology, 12*(5), 447–450. https://doi.org/10.1128/am.12.5.447-450.1964

[5] Ates, M. (2011). Review study of electrochemical impedance spectroscopy and equivalent electrical circuits of conducting polymers on carbon surfaces. *Progress in Organic Coatings, 71*, 1–10. https://doi.org/10.1016/j.porgcoat.2010.12.011

[6] Yang, L., & Bashir, R. (2008). Electrical/electrochemical impedance for rapid detection of foodborne pathogenic bacteria. *Biotechnology Advances, 26*, 135–150. https://doi.org/10.1016/j.biotechadv.2007.10.003

[7] Pethig, R., & Markx, G. H. (1997). Applications of dielectrophoresis in biotechnology. *Trends in Biotechnology, 15*, 426–432. https://doi.org/10.1016/S0167-7799(97)01096-2

[8] Pethig, R. (1979). *Dielectric and electronic properties of biological materials*. Wiley.

[9] Borkholder, D. A. (1998). *Cell-based biosensors using microelectrodes* (Ph.D. dissertation). Rochester Institute of Technology.

[10] Firstenberg-Eden, R., & Eden, G. (1984). *Impedance microbiology*. Research Studies Press Ltd.

[11] Wawerla, M., Stolle, A., Schalch, B., & Eisgruber, H. (1999). Impedance microbiology: Applications in food hygiene. *Journal of Food Protection, 62*, 1488–1496. https://doi.org/10.4315/0362-028X-62.12.1488

[12] Ur, A., & Brown, D. F. J. (1975). Impedance monitoring of bacterial activity. *Journal of Medical Microbiology, 8*, 19–28. https://doi.org/10.1099/00222615-8-1-19

[13] Silley, P., & Forsythe, S. (1996). Impedance microbiology: A rapid change for microbiologists. *Journal of Applied Bacteriology, 80*, 233–243. https://doi.org/10.1111/j.1365-2672.1996.tb03215.x

[14] Owens, J. D., Thomas, D. S., Thompson, P. S., & Timmerman, W. (1989). Indirect conductimetry: A novel approach to the conductimetric enumeration of microbial populations. *Letters in Applied Microbiology, 9*, 245–249. https://doi.org/10.1111/j.1472-765X.1989.tb00337.x

[15] Ghafar-Zadeh, E., Sawan, M., Chodavarapu, V. P., & Hosseini-Nia, T. (2010). Bacteria growth monitoring through a differential CMOS capacitive sensor. *IEEE Transactions on Biomedical Circuits and Systems, 4*(4), 232–238. https://doi.org/10.1109/TBCAS.2010.2048430

[16] Yao, L., Hajj-Hassan, M., Ghafar-Zadeh, E., Shabani, A., Chodavarapu, V., & Zourob, M. (2008, May). CMOS capacitive sensor system for bacteria detection using phage organisms. *2008 Canadian Conference on Electrical and Computer Engineering*, 000877–000880. IEEE.

[17] Rydosz, A., Brzozowska, E., Górska, S., Wincza, K., Gamian, A., & Gruszczynski, S. (2016). A broadband capacitive sensing method for label-free bacterial LPS detection. *Biosensors and Bioelectronics, 75*, 328–336. https://doi.org/10.1016/j.bios.2015.08.019

[18] Jo, N., Kim, B., Lee, S. M., Oh, J., Park, I. H., Lim, K. J., Shin, J. S., & Yoo, K. H. (2018). Aptamer-functionalized capacitance sensors for real-time monitoring of bacterial growth and antibiotic susceptibility. *Biosensors and Bioelectronics, 102*, 164–170.

Downloads

Published

03/15/2025

Issue

Section

المقالات

How to Cite

Mujahed, A. ., & Alqaisi, M. (2025). Detection Of Escherichia coli In Water Using Capacitance Biosensor. International Innovations Journal of Applied Science, 2(1). https://doi.org/10.61856/mr5mqp71